Oil and Gas Facilities training

How to Tune the EOS in your Process Simulation Software?

Process simulation computer programs are excellent tools for designing or evaluating gas processing plants, chemical plants, oil refineries or pipelines. In these simulation programs, most of the thermodynamic properties are calculated by an equation of state (EOS). However, none of the equations of state is perfect and often some sort of tuning must be done prior to their applications. Some tuning is already done by researchers and has been embedded in the data base of these simulation programs. In dealing with non-standard or complex systems, the user should check the validity and accuracy of the selected thermodynamic package (i.e. EOS) in the simulation programs prior to attempting to run the desired simulation. Often the users find that tuning is required. This can be done by performing a series of vapor liquid equilibria (VLE) calculations such as dew point, bubble point or flash calculations and comparing the results with the field data or experimental data. If the accuracy is not within acceptable range, then the EOS should be tuned to improve its accuracy.

In this tip of the month (TOTM), we will demonstrate how the binary interaction parameters are tuned in a simulation program to improve the accuracy of a selected EOS. For this purpose, we will demonstrate how the accuracy of the bubble point pressure prediction of a ternary system of carbon dioxide, pentadecane, and hexadecane can be improved.

To learn more about this Tip and past Tips of the Month, visit the Tip of the Month.