Ideal Water Content Correlation for Sweet Natural Gas

Written on January 2, 2018 at 3:45 pm, by

The analysis of Figures 1 through 3 indicates that the for pressures up to 100 psia (690 kPa) the Raoult’s law water content deviations from real state water content are within about +4% and -4%.  The water vapor content of natural gases in equilibrium with water is commonly estimated from Figure 6.1 of Campbell book [1]Continue Reading