{"id":2283,"date":"2016-04-06T09:35:36","date_gmt":"2016-04-06T14:35:36","guid":{"rendered":"http:\/\/www.jmcampbell.com\/tip-of-the-month\/?p=2283"},"modified":"2016-04-14T14:18:26","modified_gmt":"2016-04-14T19:18:26","slug":"benefits-of-having-side-water-draw-in-a-condensate-stabilizer-column-part-1","status":"publish","type":"post","link":"http:\/\/www.jmcampbell.com\/tip-of-the-month\/2016\/04\/benefits-of-having-side-water-draw-in-a-condensate-stabilizer-column-part-1\/","title":{"rendered":"Benefits of Having Side Water-Draw in a Condensate Stabilizer Column &#8211; Part 1"},"content":{"rendered":"<p>This tip will investigate the benefits of having a water-draw in a condensate stabilizer. It will use a commercial simulation software to simulate the performance of an operating stabilizer. In order to take into account the non-ideality of water, the tip will perform three-phase (vapor, liquid hydrocarbon, and aqueous phases) calculations on the trays with excessive water rates. Specifically, it will study the impact of feed water rate in the raw condensate stream on the reboiler and condenser duties. It will also study water removal by water-draw pan, and the optimum location of water-draw tray in the column. For a case study the tip will determine the optimum location of water-Draw tray by maximizing water removal from water-draw tray and minimizing the reboiler and condenser duties.<\/p>\n<p>If the vapor \u2013 liquid equilibrium conditions in the distillation tower allow the water entering the column with the feed to leave in either the bottom product or in the overhead distillate product, then no special provisions are needed to remove the water from the fractionator. A key exception here is the probability of free water accompanying the feed stream due a malfunctioning upstream three-phase feed separator. If the distillate product is a liquid and the water condenses along with the distillate and re\ufb02ux streams then the overhead accumulator can be configured as a three-phase separator. A more dif\ufb01cult situation exists if the water condenses within the tower because the overhead temperature is too cool and the bottoms temperature is too hot to allow the water to leave in the product streams. The most common example of this condition is found in the condensate stabilizer.<\/p>\n<p>Liquid water build-up can reduce capacity and, depending on the \ufb02uid composition, promote corrosion. Eventually the water build-up will cause the tower to \ufb02ood and a major disruption in tower operation results as the water leaves the column. Once the water has left the column, operation will return to normal until the cycle repeats and the water build-up once again produces a \ufb02ooding condition. The time between cycles can be anywhere from hours to weeks depending on the amount of water entering the stabilizer.<\/p>\n<p>One solution to the water build-up condition is to provide a water draw pan on the trays where liquid water is expected to condense. Figure 1 [1] is an example of a water draw for a tray-distillation column.\u00a0 The water draw pan is not sized to provide a good separation between water and hydrocarbon liquid so the \ufb02uid leaving the column is routed to an adequately sized liquid-liquid separator where the water is removed for further processing and the hydrocarbon liquid is routed back to the distillation column [2].<\/p>\n<figure id=\"attachment_2284\" aria-describedby=\"caption-attachment-2284\" style=\"width: 300px\" class=\"wp-caption aligncenter\"><img data-recalc-dims=\"1\" decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-2284\" src=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig1.png?resize=300%2C233\" alt=\"Figure 1. Water Draw Tray Arrangement [1]\" width=\"300\" height=\"233\" \/><figcaption id=\"caption-attachment-2284\" class=\"wp-caption-text\">Figure 1. Water Draw Tray Arrangement [1]<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<p><strong>Case Study<\/strong><\/p>\n<p>Table 1 presents the compositions (mol %) of a raw condensate mixture studied. This table also presents the required heavy end properties (Molecular Weight, Specific Gravity, and Volume Average Boiling Point) and the conditions of the feed stream.<\/p>\n<p><img data-recalc-dims=\"1\" decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-2285\" src=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Tab1.jpg?resize=697%2C518\" alt=\"Tab1\" width=\"697\" height=\"518\" srcset=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Tab1.jpg?w=697 697w, https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Tab1.jpg?resize=300%2C223 300w\" sizes=\"auto, (max-width: 697px) 100vw, 697px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>Figure 2 presents a simplified process flow diagram for the case study. The tip utilized the\u00a0front mixer to vary the feed water rate for the simulation purpose only. The use of the heat exchanger (HEX) will lower the reboiler and condenser duties. Table 2 presents the stabilizer column specifications. Note the difference between water <u>draw<\/u> from within the column and water <u>drain<\/u> from the V-4 reflux drum.<\/p>\n<figure id=\"attachment_2286\" aria-describedby=\"caption-attachment-2286\" style=\"width: 549px\" class=\"wp-caption aligncenter\"><img data-recalc-dims=\"1\" decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-2286\" src=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig2.png?resize=549%2C518\" alt=\"Figure 2. A simplified stabilizer column with side water-draw\" width=\"549\" height=\"518\" srcset=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig2.png?w=549 549w, https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig2.png?resize=300%2C283 300w\" sizes=\"auto, (max-width: 549px) 100vw, 549px\" \/><figcaption id=\"caption-attachment-2286\" class=\"wp-caption-text\">Figure 2. A simplified stabilizer column with side water-draw<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<p>Based on the information in Tables 1 and 2, and the process flow diagram of Figure 2, the tip performed simulation using the Soave-Redlich-Kwong (SRK) equation of state [3] in ProMax [4] software.<\/p>\n<p><img data-recalc-dims=\"1\" decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-2287\" src=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Tab2.jpg?resize=432%2C238\" alt=\"Tab2\" width=\"432\" height=\"238\" srcset=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Tab2.jpg?w=432 432w, https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Tab2.jpg?resize=300%2C165 300w\" sizes=\"auto, (max-width: 432px) 100vw, 432px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Simulation Results:<\/strong><\/p>\n<p>Figure 3 present the simulation results for the base case without side water-draw. The total water rate on the x-axis represents the sum of water rates in the vapor, light liquid (mostly hydrocarbons), and heavy liquid (mostly water) phases at any given tray in the column. The feed water range is from 940 to 1500 lbmole\/d (427 to 1500 kmol\/d). If the feed water is less than 940 lbmole (427 kmol\/d) no heavy liquid (aqueous) phase is formed inside the column and water side draw rate will be zero.\u00a0 Figure 3 indicates if the feed water rate increases above 1200 lbmole\/d (545 kmol\/d), the maximum total water rate location shifts from tray 11 down to 18. In an actual plant a free water knockout drum (three-phase separator) ahead of the stabilizer removes the excess water to minimize the heating requirement. The feed water rate above 1200 lbmole\/d (545 kmol\/d) to the stabilizer column is unrealistic and shown here only for demonstration purposes.<\/p>\n<p>In addition to the base case, the tip simulated two cases with the side water-draw located at tray number 7 or 8. Table 3 presents the summary of simulation results for the base case and the two cases with side water-draw. For the base case without the water draw, at higher feed water rate some of the water leaves with stabilized condensate (C<sub>5+<\/sub>).<\/p>\n<figure id=\"attachment_2288\" aria-describedby=\"caption-attachment-2288\" style=\"width: 721px\" class=\"wp-caption aligncenter\"><img data-recalc-dims=\"1\" decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-2288\" src=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig3.jpg?resize=721%2C439\" alt=\"Figure 3. Total water molar rate profile in the stabilizer column without side water-draw as a function water rate in the feed\" width=\"721\" height=\"439\" srcset=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig3.jpg?w=721 721w, https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig3.jpg?resize=300%2C183 300w\" sizes=\"auto, (max-width: 721px) 100vw, 721px\" \/><figcaption id=\"caption-attachment-2288\" class=\"wp-caption-text\">Figure 3. Total water molar rate profile in the stabilizer column without side water-draw as a function water rate in the feed<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<p><img data-recalc-dims=\"1\" decoding=\"async\" loading=\"lazy\" class=\"aligncenter wp-image-2289\" src=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Tab3.jpg?resize=700%2C657\" alt=\"Tab3\" width=\"700\" height=\"657\" srcset=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Tab3.jpg?w=814 814w, https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Tab3.jpg?resize=300%2C282 300w, https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Tab3.jpg?resize=768%2C721 768w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #000000; font-family: Times New Roman;\">Figure 4a indicates that the presence of side water-draw at tray 7 shifts the maximum total water rate from tray 10 (Figure 3) to 6 for lower feed water rates and from tray 18 (Figure 3) to 10 for higher feed water rates, respectively. Figures 4a and 4b also indicate that the side water-draw at tray 7 removes water effectively for low feed water rates. As shown in Table 3, at higher feed water rate, the reboiler and condenser duties decrease considerably compared to the base case. Table 3 also indicates that the HEX (feed-bottoms exchanger) duty remains the same for all three cases because there was no material change in its flows and temperatures. <\/span><\/p>\n<p>&nbsp;<\/p>\n<figure id=\"attachment_2290\" aria-describedby=\"caption-attachment-2290\" style=\"width: 638px\" class=\"wp-caption aligncenter\"><img data-recalc-dims=\"1\" decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-2290\" src=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig4.jpg?resize=638%2C365\" alt=\"Figure 4a. Total water molar rate profile in the stabilizer column with side water-draw at tray 7 as a function water rate in the feed (full range)\" width=\"638\" height=\"365\" srcset=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig4.jpg?w=638 638w, https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig4.jpg?resize=300%2C172 300w\" sizes=\"auto, (max-width: 638px) 100vw, 638px\" \/><figcaption id=\"caption-attachment-2290\" class=\"wp-caption-text\">Figure 4a. Total water molar rate profile in the stabilizer column with side water-draw at tray 7 as a function water rate in the feed (full range)<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<figure id=\"attachment_2291\" aria-describedby=\"caption-attachment-2291\" style=\"width: 642px\" class=\"wp-caption aligncenter\"><img data-recalc-dims=\"1\" decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-2291\" src=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig4b.jpg?resize=642%2C378\" alt=\"Figure 4b. Total water molar rate profile in the stabilizer column with side water-draw at tray 7 as a function water rate in the feed (lower range)\" width=\"642\" height=\"378\" srcset=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig4b.jpg?w=642 642w, https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig4b.jpg?resize=300%2C177 300w\" sizes=\"auto, (max-width: 642px) 100vw, 642px\" \/><figcaption id=\"caption-attachment-2291\" class=\"wp-caption-text\">Figure 4b. Total water molar rate profile in the stabilizer column with side water-draw at tray 7 as a function water rate in the feed (lower range)<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<p>In order to maximize water removal for higher feed water rate, the tip moved the side water-draw from tray 7 to 8. Table 3 clearly indicates that water-draw at tray 7 give higher water recovery percent for lower feed water rates up to 1200 lbmole\/d (545 kmol\/d) and water-draw at tray 8 give higher water recovery for higher feed water rate.\u00a0 Figure 5 presents the total water flow rate profile within the column with side water-draw at tray 8 as a function of feed water rate. This figure demonstrates the effectiveness of the side water-draw.<\/p>\n<figure id=\"attachment_2292\" aria-describedby=\"caption-attachment-2292\" style=\"width: 690px\" class=\"wp-caption aligncenter\"><img data-recalc-dims=\"1\" decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-2292\" src=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig5.jpg?resize=690%2C462\" alt=\"Figure 5. Total water molar rate profile in the stabilizer column with side water-draw at tray 8 as a function water rate in the feed (higher range)\" width=\"690\" height=\"462\" srcset=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig5.jpg?w=690 690w, https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig5.jpg?resize=300%2C201 300w\" sizes=\"auto, (max-width: 690px) 100vw, 690px\" \/><figcaption id=\"caption-attachment-2292\" class=\"wp-caption-text\">Figure 5. Total water molar rate profile in the stabilizer column with side water-draw at tray 8 as a function water rate in the feed (higher range)<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<p>Figure 6 presents the water recovery percent of the feed water as a function of the feed water rate for the three cases considered.\u00a0 For the base case without the side water-draw some of the excess water leaves the column with the C<sub>5+<\/sub> stream. For this case, the excess feed water rate also increases the reboiler and condenser duties. These increases are indicative of the increased internal vapor traffic necessary to carry the water vapor out of the tower.<\/p>\n<p>Like Figures 7 and 8, Figure 6 also shows the effectiveness of side water-draw and the impact of side water-draw location.<\/p>\n<figure id=\"attachment_2300\" aria-describedby=\"caption-attachment-2300\" style=\"width: 741px\" class=\"wp-caption aligncenter\"><img data-recalc-dims=\"1\" decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-2300\" src=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig6.jpg?resize=741%2C431\" alt=\"Figure 6. Water recovery (%) as a function of the feed water rate\" width=\"741\" height=\"431\" srcset=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig6.jpg?w=741 741w, https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig6.jpg?resize=300%2C174 300w\" sizes=\"auto, (max-width: 741px) 100vw, 741px\" \/><figcaption id=\"caption-attachment-2300\" class=\"wp-caption-text\">Figure 6. Water recovery (%) as a function of the feed water rate<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<figure id=\"attachment_2295\" aria-describedby=\"caption-attachment-2295\" style=\"width: 646px\" class=\"wp-caption aligncenter\"><img data-recalc-dims=\"1\" decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-2295\" src=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig7.jpg?resize=646%2C389\" alt=\"Figure 7. Reboiler duty as a function of the feed water rate\" width=\"646\" height=\"389\" srcset=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig7.jpg?w=646 646w, https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig7.jpg?resize=300%2C181 300w\" sizes=\"auto, (max-width: 646px) 100vw, 646px\" \/><figcaption id=\"caption-attachment-2295\" class=\"wp-caption-text\">Figure 7. Reboiler duty as a function of the feed water rate<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<figure id=\"attachment_2296\" aria-describedby=\"caption-attachment-2296\" style=\"width: 647px\" class=\"wp-caption aligncenter\"><img data-recalc-dims=\"1\" decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-2296\" src=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig8.jpg?resize=647%2C401\" alt=\"Figure 8. Condenser duty as a function of the feed water rate\" width=\"647\" height=\"401\" srcset=\"https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig8.jpg?w=647 647w, https:\/\/i0.wp.com\/www.jmcampbell.com\/tip-of-the-month\/wp-content\/uploads\/2016\/04\/Fig8.jpg?resize=300%2C186 300w\" sizes=\"auto, (max-width: 647px) 100vw, 647px\" \/><figcaption id=\"caption-attachment-2296\" class=\"wp-caption-text\">Figure 8. Condenser duty as a function of the feed water rate<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<p><strong>Conclusions:<\/strong><\/p>\n<p>The simulation results for the three case studies demonstrated the effectiveness of side water-draw and the importance of water draw location in the column. Based on the results obtained, this tip presents the following observations.<\/p>\n<ol>\n<li>Commercial simulators using special convergence algorithms and thermodynamic packages are able to predict the presence of two liquid phases within distillation columns. The calculations are dif\ufb01cult to converge and it is dif\ufb01cult to predict the exact location of the liquid water phase. Therefore, it is advisable to install liquid water draw trays in two or three locations around the tray predicted by the simulator.<\/li>\n<li>Install properly sized free water knockout (three phase separator) separator to minimize the feed water rate to the stabilizer column. This assures easier\/less troublesome operation with lower utility (reboiler and condenser duties) cost.<\/li>\n<li>Side water-draw removes water\/aqueous phase effectively and reduces the reboiler duty and condenser duty.<\/li>\n<li>The optimum location of the side-draw depends on the feed water rate.<\/li>\n<li>This tip determined the optimum location of water-draw try by maximizing liquid water removal and minimizing the reboiler and condenser duties.<\/li>\n<li>The side water-draw has no impact on the heat exchanger upstream of the stabilizer column.<\/li>\n<li>As shown In Table 3, the topmost condenser duties for the three cases are 14.67, 9.00 and 8.49 MMBtu\/hr (4.3, 2.64, and 2.49 MW), respectively.\u00a0 Since fundamentally at a fixed overhead product rate,\u00a0condenser pressure and temperature the water vapor content is fixed.\u00a0 Thus a greater total overhead flow is needed to transport water as vapor out of the column to be condensed into the reflux drum and removed.\u00a0 Greater total overhead means larger condenser duty.\u00a0 It also requires a commensurately larger reboiler duty.\u00a0 With a lot of water entering the tower the condenser and reboiler might not be big enough to do the job.<\/li>\n<\/ol>\n<p>Part 2 (follow-up of this tip) will investigate the variation of water partial pressure along the column and the changes in operating variables.<\/p>\n<p>To learn more about similar cases and how to minimize operational problems, we suggest attending our <a href=\"http:\/\/petroskills.com\/course\/g4\"><strong>G4 (<\/strong>Gas Conditioning and Processing<strong>)<\/strong><\/a><strong><u>,<\/u><\/strong> <a href=\"http:\/\/petroskills.com\/course\/g5\"><strong>G5 (<\/strong>Advanced Applications in Gas Processing<strong>)<\/strong><\/a><strong>, <\/strong><a href=\"http:\/\/petroskills.com\/course\/pf81\"><strong>P81 (<\/strong>CO<sub>2<\/sub> Surface Facilities<strong>),<\/strong><\/a> and <a href=\"http:\/\/petroskills.com\/course\/pf4\"><strong>PF4 <\/strong>(Oil Production and Processing Facilities),<\/a> courses.<\/p>\n<p><em>\u00a0<\/em><\/p>\n<p><em>PetroSkills <\/em>offers consulting expertise on this subject and many others. For more information about these services, visit our website at <a href=\"http:\/\/petroskills.com\/consulting\">http:\/\/petroskills.com\/consulting<\/a>, or email us at <a href=\"mailto:consulting@PetroSkills.com\">consulting@PetroSkills.com<\/a>.<\/p>\n<p><em>By: Dr. Mahmood Moshfeghian<\/em><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>Reference:<\/strong><\/p>\n<ol>\n<li>Campbell, J.M., Gas Conditioning and Processing, Volume 2: The Equipment Modules, 9<sup>th<\/sup> Edition, 2<sup>nd<\/sup> Printing, Editors Hubbard, R. and Snow\u2013McGregor, K., Campbell Petroleum Series, Norman, Oklahoma, 2014.<\/li>\n<li>Lieberman, N. P. ; \u201cTroubleshooting Process Operation \u2013 13,\u201d Oil and Gas Journal, p. 100\u2013 102, Feb 16, 1981.<\/li>\n<li>Soave, G., Chem. Eng. Sci. 27, 1197-1203, 1972.<\/li>\n<li>ProMax 3.2, Bryan Research and Engineering, Inc, Bryan, Texas, 2016.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>This tip will investigate the benefits of having a water-draw in a condensate stabilizer. It will use a commercial simulation software to simulate the performance of an operating stabilizer. In order to take into account the non-ideality of water, the tip will perform three-phase (vapor, liquid hydrocarbon, and aqueous phases) calculations on the trays with [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[3,10],"tags":[],"coauthors":[17],"class_list":["post-2283","post","type-post","status-publish","format-standard","hentry","category-gas-processing","category-process-facilities"],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"","jetpack_shortlink":"https:\/\/wp.me\/p1pQc4-AP","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"http:\/\/www.jmcampbell.com\/tip-of-the-month\/wp-json\/wp\/v2\/posts\/2283","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.jmcampbell.com\/tip-of-the-month\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.jmcampbell.com\/tip-of-the-month\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.jmcampbell.com\/tip-of-the-month\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.jmcampbell.com\/tip-of-the-month\/wp-json\/wp\/v2\/comments?post=2283"}],"version-history":[{"count":6,"href":"http:\/\/www.jmcampbell.com\/tip-of-the-month\/wp-json\/wp\/v2\/posts\/2283\/revisions"}],"predecessor-version":[{"id":2304,"href":"http:\/\/www.jmcampbell.com\/tip-of-the-month\/wp-json\/wp\/v2\/posts\/2283\/revisions\/2304"}],"wp:attachment":[{"href":"http:\/\/www.jmcampbell.com\/tip-of-the-month\/wp-json\/wp\/v2\/media?parent=2283"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.jmcampbell.com\/tip-of-the-month\/wp-json\/wp\/v2\/categories?post=2283"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.jmcampbell.com\/tip-of-the-month\/wp-json\/wp\/v2\/tags?post=2283"},{"taxonomy":"author","embeddable":true,"href":"http:\/\/www.jmcampbell.com\/tip-of-the-month\/wp-json\/wp\/v2\/coauthors?post=2283"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}